Contact Us
- No. 8, 2nd Branch Road, Jianxin North Road, Liangjiang New Area, Chongqing, P.R.China
- +8619922856120
- Camille
- [email protected]
SCINTREX CG-5 Gravimeter Battery – High-Quality Used Geophysical Power Supply
Product Overview
We are professional suppliers of used geophysical and geophysical exploration equipment, dedicated to providing high-quality spare parts for global customers. The SCINTREX CG-5 Gravimeter Battery is a professional power supply specially designed for SCINTREX CG-5 relative gravimeters, perfectly compatible with CG-5 instruments. It features high capacity, stable power output, hot-swappable function and wide temperature adaptability, making it an essential spare part for maintaining the normal operation of CG-5 gravimeters. All our used batteries are fully tested to ensure they meet industry standards and can work stably in harsh field exploration environments, supporting high-precision gravity measurement tasks.
![]() |
Technical Parameters
- Brand & Model: SCINTREX CG-5 Gravimeter Battery
- Product Type: Geophysical Gravimeter Power Supply (Rechargeable Lithium Battery)
- Compatibility: Exclusively designed for SCINTREX CG-5 relative gravimeters
- Rated Voltage: 10.8V (10.78V nominal)
- Capacity: 6Ah, two batteries can support a full day of measurement work
- Material: High-quality lithium-ion cells, durable ABS shell
- Working Temperature: -40℃ ~ +45℃, suitable for various climate conditions
- Function: Real-time power display, hot-swappable (avoids measurement interruption)
- Charging Voltage: Compatible with 110/240V universal chargers
- Power Consumption: 4.5W at 25℃
- Condition: Used/refurbished, fully tested and functional, no leakage
- Application: Seismic survey, geological exploration, gravity measurement and other geophysical scenarios
![]() |
![]() |
Brief Instructions
1. Installation Preparation
- Power off the SCINTREX CG-5 gravimeter before installation to avoid short circuit or equipment damage.
- Check the battery for any damage (such as shell cracks or leakage) and ensure the battery contacts are clean and free of dust or oxide.
- Prepare a clean cloth to wipe the battery contacts and gravimeter battery compartment if necessary, ensuring good electrical connection.
2. Installation Steps
- Open the battery compartment of the CG-5 gravimeter according to the instrument manual, and align the battery contacts with the compartment contacts.
- Gently insert the battery into the compartment until it is firmly fixed (do not force insertion to avoid damaging the contacts or battery).
- Close the battery compartment cover and secure it properly; for hot-swapping, directly replace the battery without powering off the instrument to avoid measurement interruption.
- Power on the gravimeter and check the power display to ensure the battery is properly connected and supplies power normally.
3. Usage & Maintenance
- Avoid mixing this battery with other types or brands of batteries to prevent equipment failure or battery leakage.
- Charge the battery with a compatible 110/240V charger; do not overcharge or over-discharge to extend its service life.
- Keep the battery away from sharp objects, high temperature, open flames and corrosive substances; avoid severe impact or extrusion.
- Regularly inspect the battery shell and contacts; if leakage, bulging or damage is found, stop using it immediately and dispose of it according to local environmental protection regulations.
- When not in use for a long time, store the battery in a dry, cool and ventilated environment with 50%-70% power, and charge it every 3 months to maintain battery performance.